Identity, by HPLC
The compound in the vial is run against a reference standard. A confirmed identity means the peak matches the compound on the label, not something else.
Each lot is analyzed by an independent ISO/IEC 17025 laboratory before release. Find your compound below and open the certificate the laboratory signed.
Rows marked No report published have no document on this site yet. That is an accurate statement of what Helion has published, not a broken link, and it is not a claim about where any lot sits at a laboratory.
| Compound | SKU | Purity | Issued | Status | Document |
|---|
Clear the filters to see every compound in the catalog.
Six assays and a fentanyl screen, each run by the independent laboratory. This is what the numbers on a report mean.
The compound in the vial is run against a reference standard. A confirmed identity means the peak matches the compound on the label, not something else.
The share of the sample that is the labeled compound. Helion’s release floor is 99%+ identity purity; the measured figure is printed on every certificate.
The measured mass in the vial against the labeled amount, so a 10mg vial can be checked against what it actually holds.
Bacterial endotoxin measured by the limulus amebocyte lysate assay and reported in EU/mL, so the value is on record rather than assumed.
The sample is screened for microbial growth. Every published Helion lot returns No growth, and that line is printed on the certificate alongside the method.
Inductively coupled plasma mass spectrometry against the USP <233> elemental impurity limits. Every published lot reports all below limits.
Each lot is screened for fentanyl and the certificate carries the result. It is a contamination check on the material, and it is run on every lot we publish.
Every ILS certificate prints a QR code and an access code. Scan it and the laboratory’s own portal confirms the report, so you are not taking our word for the document.
Six assays, each performed by the independent laboratory: identity by HPLC against a reference standard, purity as HPLC peak area, net content by mass spectrometry, sterility by PCR, bacterial endotoxin by LAL and heavy metals by ICP-MS, plus a fentanyl screen. The signed document carries the certificate number, the date and the laboratory’s QR verification code.
Email support@helionresearchusa.com with your order number. If the report has cleared testing we send it directly. If it has not, we say so rather than send you something else.
If a delivered lot is independently re-verified within 30 days and tests below its stated identity-purity floor or shows endotoxin above the level reported on its Certificate of Analysis, we provide a refund and replacement. Full wording lives in returns and re-verification and in our terms.
Send your order number. You will get a straight answer about whether that report exists, not a substitute document.